Total Dynamic Head (TDH) Calculator
Add static head, pressure head, friction loss and fitting losses to get the total head the pump must deliver. Enter the pipe and the flow, and the calculator works out the velocity, Reynolds number and friction factor along the way.
| Quantity | Value |
|---|---|
| Velocity | 1.768 m/s |
| Reynolds number | 176100 |
| Friction factor f | 0.0189 |
| Static head | 20 m |
| Pressure head | 0 m |
| Friction loss h_f | 3.013 m |
| Minor loss h_m | 0.7972 m |
| Total dynamic head | 23.81 m |
Next step: Send 23.81 m to the pump power calculator →
Formula
| Symbol | Meaning | Unit |
|---|---|---|
| TDH | Total dynamic head | m |
| z_d − z_s | Static head: discharge elevation minus suction elevation | m |
| p_d − p_s | Pressure rise across the pump | Pa |
| ρ | Liquid density | kg/m³ |
| g | Standard gravity, 9.80665 m/s² | m/s² |
| h_f | Friction (major) loss | m |
| h_m | Minor loss from fittings and valves | m |
| f | Darcy friction factor | — |
| L | Pipe length | m |
| D | Pipe inside diameter | m |
| v | Mean flow velocity | m/s |
| Q | Volumetric flow rate | m³/s |
| Re | Reynolds number | — |
| ν | Kinematic viscosity | m²/s |
| ε | Pipe roughness | m |
| ΣK | Sum of fitting loss coefficients | — |
The last line is the Swamee–Jain formula for the turbulent friction factor. Below Re 2300 the flow is laminar and . Between Re 2300 and 4000 the flow is transitional and the friction factor is unreliable — the calculator warns you when you land there.
Worked examples
Example 1 — SI: 50 m³/h through 100 mm pipe
- Water at 20 °C: ,
- Flow: ; pipe: , ,
- Fittings: ; static head: ; same pressure at both ends
- Velocity:
- Reynolds number: (turbulent)
- Friction factor (Swamee–Jain):
- Velocity head:
- Friction loss:
- Minor loss:
The pressure head is zero here because the suction and discharge pressures are equal — only the elevation and the losses count.
Example 2 — US: the same system in US units
- Flow: ; pipe: , ,
- Fittings: ; static head: ; same pressure at both ends
- Velocity: ; Reynolds number: ; friction factor:
- Friction loss: ; minor loss:
Same pipe, same flow — 23.8 m is 78.1 ft. Reynolds number and friction factor are dimensionless, so they do not change with the unit system.
Assumptions and limits
- Incompressible liquid only. Density is treated as constant along the pipe, so this is for liquids, not gases.
- Steady flow. The calculation is for a constant flow rate; it does not cover water hammer or start-up transients.
- Swamee–Jain is an explicit approximation of the Colebrook relation for turbulent flow. Below Re 2300 the laminar relation applies. In the transitional range, Re 2300 to 4000, neither relation is reliable and the calculator shows a warning.
- Fitting K values are typical values, not exact for every fitting. The actual K depends on the exact geometry — use the manufacturer’s data for final design, and edit any K in the fitting list to match.
- The roughness default (0.045 mm) is commercial steel only, from the worked example. Enter the value for your own pipe material.
- Entrance and exit losses are not added automatically. If they apply to your system, include them in the ΣK total (enter ΣK directly).
- Head is in metres (or feet) of the liquid being pumped, not in bar or psi — the pressure head term converts the pressure difference using the density you enter.
Next step
Got a TDH value? Size the motor for it: Pump power calculator
FAQ
What counts as static head?
The vertical distance the pump must lift the liquid: the discharge elevation minus the suction elevation (z_d − z_s). Measure both elevations from the same datum — usually the liquid surface at the suction and the discharge point or the liquid surface at the discharge. Pipe length and friction do not belong in static head; they are counted separately as h_f.
Why is the transitional range (Re 2300–4000) unreliable?
In that range the flow keeps switching between laminar and turbulent, so the friction factor is not settled: the laminar relation f = 64/Re no longer applies, and the Swamee–Jain formula is a turbulent-flow relation. The true friction factor can sit well away from either one. The calculator warns you when you land there — change the pipe size or the flow so the design point sits clearly in laminar or turbulent flow, or verify the loss by test.
Should I use the inside or the outside diameter?
Inside diameter. The velocity, Reynolds number and friction loss all depend on the bore the liquid actually flows through. The outside diameter is larger, so using it would understate the velocity and the losses. If you only know the nominal size (DN/NPS), convert it to the actual inside diameter from the pipe schedule and wall thickness.
What roughness should I use if I do not know it?
Use the measured or typical value for your pipe material from the manufacturer — do not guess. The 0.045 mm default in this calculator is commercial steel, from the worked example only. A smoother or rougher pipe changes the friction factor, so the default is a starting point, not a specification.
Can static head be negative?
Yes. Static head is the discharge elevation minus the suction elevation, so if the discharge point is below the suction liquid level the static head is negative and it reduces the total head. Enter it with a minus sign and the calculator handles it.
Sources
- Darcy–Weisbach head loss and the Swamee–Jain friction-factor relation — standard fluid-mechanics textbook relations
- Engineering ToolBox, "Minor (Dynamic) Loss Coefficients for Pipe and Tube System Components" — fitting K values
- Water density at temperature — see the water vapor pressure and density table on this site
For preliminary estimates only. Verify against manufacturer data and the governing standard before purchase or installation.