pumpcalc

Water Vapor Pressure and Density Table (0–100 °C)

Saturation vapor pressure and density of water from 0 to 100 °C, in 5 °C steps. Vapor pressure is what you need for NPSH and cavitation checks; density is what you need to convert between pressure and head.

Lowest temperature in the table, 0–100 °C.
Highest temperature in the table, 0–100 °C.
Temperature (°C)Saturation vapor pressure (kPa)Saturation vapor pressure (bar)Saturation vapor pressure (psi)Density (kg/m³)Vapor-pressure head (m of water)
00.6110.00610.089999.80.062
50.8730.00870.12710000.089
101.2280.01230.178999.70.125
151.7060.01710.247999.10.174
202.3390.02340.339998.20.239
253.170.03170.469970.324
304.2470.04250.616995.60.435
355.6290.05630.8169940.577
407.3850.07391.071992.20.759
459.5950.0961.392990.20.988
5012.3520.12351.7929881.275
5515.7630.15762.286985.71.631
6019.9470.19952.893983.22.069
6525.0430.25043.632980.62.604
7031.2020.3124.526977.83.254
7538.5970.3865.598974.84.037
8047.4160.47426.877971.84.975
8557.8680.57878.393968.66.092
9070.1830.701810.179965.37.414
9584.6090.846112.272961.98.969
100101.4181.014214.709958.410.791

Showing 21 of 21 rows. Vapor-pressure head is pv / (ρg) in metres of water.

Downloads the full 21-row table as a CSV file.

Look up any temperature

Enter a temperature between 0 and 100 °C for the interpolated value.
Saturation vapor pressure
Enter a temperature to look up

Interpolated from the same IAPWS-95 and Kell (1975) formulations as the table — not a straight line between two rows. Source: IAPWS-95, checked 2026-11-17.

How the table was made

The rows are computed, not measured. Saturation vapor pressure comes from the IAPWS Formulation 1995 equation (Wagner and Pruß 2002), and density from the Kell (1975) correlation — the same formulations CoolProp implements. Vapor-pressure head is hv=pv/(ρg)h_v = p_v / (\rho g) in metres of water, with g=9.80665 m/s2g = 9.80665\ \text{m/s}^2.

The table was checked against the six anchor points in our formulas reference (0, 20, 40, 60, 80 and 100 °C): all six agree within 0.24%, inside the 0.5% tolerance. At 100 °C the vapor pressure is 101.4 kPa — essentially atmospheric pressure, which is why water boils there. Density peaks near 4 °C, so cold water is slightly denser than water at 20 °C.

Data source

Data checked 2026-11-17. Rows are computed from the formulations above, not laboratory measurements; the anchor agreement is 0.24% against published reference values.

For preliminary estimates only. Verify against manufacturer data and the governing standard before purchase or installation.

Reviewed by pumpcalc · Last updated 2026-11-17