Water Vapor Pressure and Density Table (0–100 °C)
Saturation vapor pressure and density of water from 0 to 100 °C, in 5 °C steps. Vapor pressure is what you need for NPSH and cavitation checks; density is what you need to convert between pressure and head.
| Temperature (°C) | Saturation vapor pressure (kPa) | Saturation vapor pressure (bar) | Saturation vapor pressure (psi) | Density (kg/m³) | Vapor-pressure head (m of water) |
|---|---|---|---|---|---|
| 0 | 0.611 | 0.0061 | 0.089 | 999.8 | 0.062 |
| 5 | 0.873 | 0.0087 | 0.127 | 1000 | 0.089 |
| 10 | 1.228 | 0.0123 | 0.178 | 999.7 | 0.125 |
| 15 | 1.706 | 0.0171 | 0.247 | 999.1 | 0.174 |
| 20 | 2.339 | 0.0234 | 0.339 | 998.2 | 0.239 |
| 25 | 3.17 | 0.0317 | 0.46 | 997 | 0.324 |
| 30 | 4.247 | 0.0425 | 0.616 | 995.6 | 0.435 |
| 35 | 5.629 | 0.0563 | 0.816 | 994 | 0.577 |
| 40 | 7.385 | 0.0739 | 1.071 | 992.2 | 0.759 |
| 45 | 9.595 | 0.096 | 1.392 | 990.2 | 0.988 |
| 50 | 12.352 | 0.1235 | 1.792 | 988 | 1.275 |
| 55 | 15.763 | 0.1576 | 2.286 | 985.7 | 1.631 |
| 60 | 19.947 | 0.1995 | 2.893 | 983.2 | 2.069 |
| 65 | 25.043 | 0.2504 | 3.632 | 980.6 | 2.604 |
| 70 | 31.202 | 0.312 | 4.526 | 977.8 | 3.254 |
| 75 | 38.597 | 0.386 | 5.598 | 974.8 | 4.037 |
| 80 | 47.416 | 0.4742 | 6.877 | 971.8 | 4.975 |
| 85 | 57.868 | 0.5787 | 8.393 | 968.6 | 6.092 |
| 90 | 70.183 | 0.7018 | 10.179 | 965.3 | 7.414 |
| 95 | 84.609 | 0.8461 | 12.272 | 961.9 | 8.969 |
| 100 | 101.418 | 1.0142 | 14.709 | 958.4 | 10.791 |
Showing 21 of 21 rows. Vapor-pressure head is pv / (ρg) in metres of water.
Downloads the full 21-row table as a CSV file.
Look up any temperature
Interpolated from the same IAPWS-95 and Kell (1975) formulations as the table — not a straight line between two rows. Source: IAPWS-95, checked 2026-11-17.
How the table was made
The rows are computed, not measured. Saturation vapor pressure comes from the IAPWS Formulation 1995 equation (Wagner and Pruß 2002), and density from the Kell (1975) correlation — the same formulations CoolProp implements. Vapor-pressure head is in metres of water, with .
The table was checked against the six anchor points in our formulas reference (0, 20, 40, 60, 80 and 100 °C): all six agree within 0.24%, inside the 0.5% tolerance. At 100 °C the vapor pressure is 101.4 kPa — essentially atmospheric pressure, which is why water boils there. Density peaks near 4 °C, so cold water is slightly denser than water at 20 °C.
Data source
- Wagner, W. and Pruß, A. (2002). The IAPWS Formulation 1995 for the Thermodynamic Properties of Ordinary Water Substance for General and Scientific Use. J. Phys. Chem. Ref. Data 31(2):387–535.
- Kell, G. S. (1975). Density, Thermal Expansivity, and Compressibility of Liquid Water from 0 to 150 °C. J. Chem. Eng. Data 20(1):97–105.
- Anchor points: our formulas reference, section 4 (OpenStax Chemistry App. E; Saylor General Chemistry App. F; IAPWS-95 table via processconvert).
Data checked 2026-11-17. Rows are computed from the formulations above, not laboratory measurements; the anchor agreement is 0.24% against published reference values.
Related calculators
- NPSH calculator — use the vapor pressure from this table to check whether your pump cavitates.
- Pressure to head calculator — convert a vapor pressure into metres of water head, or a head back into pressure, using the density from this table.
For preliminary estimates only. Verify against manufacturer data and the governing standard before purchase or installation.