pumpcalc

NPSH Available Calculator

Work out the net positive suction head available at a pump inlet — the margin between the suction pressure and the liquid’s vapour pressure, expressed as a head. If it falls below what the pump requires, the pump cavitates.

Units:
Absolute pressure at the liquid surface — 101.325 kPa at sea level, lower at altitude.
Vapour pressure and density below are filled in from the water table at this temperature.
From the water table at the temperature above.
From the water table at the temperature above.
Liquid surface above the pump centreline is positive; below it (suction lift) is negative.
Friction and fitting losses in the suction line.
From the pump curve at the duty flow. Shows the NPSHa − NPSHr margin.
NPSH available (NPSHa)
10.11 m

Next step: Pump power calculator →

Formula

NPSHa=pabs−pvρg+hs−hfNPSHa = \frac{p_{abs} - p_v}{\rho g} + h_s - h_f

SymbolMeaningUnit
NPSHaNet positive suction head availablem
p_absAbsolute pressure at the suction liquid surfacePa
p_vSaturation vapour pressure at the liquid temperaturePa
ρLiquid densitykg/m³
gStandard gravity, 9.80665 m/s²m/s²
h_sSuction height — liquid surface above the pump centreline is positivem
h_fSuction line lossm

The first term is the pressure head at the liquid surface above vapour pressure. A flooded suction (liquid above the pump) adds head; a suction lift subtracts it; friction in the suction line subtracts further. Enter the temperature and the calculator fills in vapour pressure and density from the water table — override either field for another liquid.

Worked examples

Example 1 — SI: suction lift, water at 20 °C

The pump must lift water 3 m, so the available suction head is 6.11 m.

Example 2 — SI: flooded suction, water at 80 °C

Hot water has far less NPSHa than cold water in the same layout: vapour pressure eats 4.97 m of head at 80 °C, against 0.24 m at 20 °C.

The table value pv=47.41 kPap_v = 47.41\ \text{kPa} is rounded: the IAPWS-95 value this calculator uses at 80 °C is 47.42 kPa (47.4158 kPa), a 0.01% difference that leaves the result at 7.16 m.

Example 3 — US: the same suction lift in feet

That is the same 6.11 m as Example 1, allowing for rounding.

Assumptions and limits

Next step

Once the suction checks out, work out the power the pump needs: Pump power calculator

FAQ

What is the difference between NPSHa and NPSHr?

NPSHa is what the suction system delivers: the pressure head at the pump inlet above vapour pressure, from the layout, the liquid and the site. NPSHr is what the pump needs at a given flow, read from the manufacturer’s pump curve. The pump runs without cavitation only when NPSHa exceeds NPSHr — and by whatever margin the pump manufacturer recommends.

Why does hot water cavitate more easily than cold water?

Vapour pressure rises steeply with temperature: water at 20 °C has p_v = 2.34 kPa, at 80 °C it is 47.4 kPa. The (p_abs − p_v) term shrinks, so NPSHa falls even if nothing else in the suction line changes. Hot-water and boiler-feed pumps therefore need a flooded suction or a pressurised source to keep NPSHa up.

How does altitude affect NPSHa?

The suction surface pressure is usually atmospheric pressure, and atmospheric pressure falls with altitude — so p_abs is lower than the sea-level 101.325 kPa and NPSHa drops by the same head. Enter the local absolute pressure at the site, not the sea-level value.

How much margin should I allow above NPSHr?

There is no verified universal margin value, so this site does not state one. Follow the pump manufacturer’s recommended margin for the pump and duty.

What does a negative NPSHa mean?

The liquid would flash to vapour at the pump inlet before the pump can do any work — the pump cavitates and cannot deliver its rated head. Raise the liquid level, shorten or enlarge the suction line to cut h_f, cool the liquid, or raise the suction pressure.

Sources

For preliminary estimates only. Verify against manufacturer data and the governing standard before purchase or installation.

Reviewed by pumpcalc · Last updated 2026-11-17